S200: Drive Family Power Specifications

NOTE: Unless otherwise specified, the specifications are worse-case limits and apply over the specified operating ambient temperature and over the specified operating line voltage.

 
AC Input
DC Input
S20260
S20360
S20660
S20330
S20630
Peak Output Current (RMS)1
   (0 to 40°C) Ambient (ARMS)
4.5
9.0
18.0
9.0
18.0
Minimum Peak Current Time
   (Starting from 0 amps) seconds
3.0
3.0
3.0
3.0
3.0
Cont. Output Current Convection2
   (0 to 30° C) amb (ARMS)
2.3
4.5
9.0
4.5
7.5
   40° C amb (ARMS)
1.5
3.0
6.0
3.0
6.0
   50° C amb (ARMS)
1.0
2.0
4.0
2.0
4.0
Peak Output Power
   240 VAC (VA) 3 Phase
1500
3000
6000
-
-
   120 VAC (VA) 1 Phase
750
1500
2400
-
-
   75 VDC (VA)
-
-
-
750
1500
Drive Continuous Output Power
   240 VAC (VA) 3 Phase (watts)
600
1100
2000
-
-
   240 VAC (VA) 1 Phase (watts)
500
900
1500
-
-
   120 VAC (VA) 1 Phase (watts)
250
450
-
-
-
   75 VDC (VA) (watts)
-
-
-
250
500
Continuous Motor Shaft Power @ 3000 RPM (Nominal Bus -10%)
   (0 to 30° C) amb (watts)
300
750
1500
180
315
   40° C amb (watts)
200
500
1000
125
250
RMS Line Current at Continuous Output Power
   240 VAC 3 Phase (ARMS)
2.7
5.0
9.0
-
-
   240 VAC 1 Phase (ARMS)
3.4
6.5
12.04
-
-
   120 VAC 1 Phase (ARMS)
3.4
6.5
12.04
-
-
+BUS Current — 75 VDC at Continuous Output Power
   Average (Adc)
-
-
-
3.0
6.7
   Instantaneous Peak (Apeak)
-
-
-
12.7
25.5
Power Dissipation at Pcont (watts)
17
29
60
8
12
Shunt Regulator
   Peak Power kW (500 mSec)
4.4
@36Ω
6.4
@25Ω
10
@15Ω
-
-
   Continuous Power (watts)
440
@36Ω
640
@25Ω
1000
@15Ω
-
-
   Maximum Regen Duty Cycle (%)
10
@36Ω
10
@25Ω
10
@15Ω
-
-
   Regen Resistance (Ω)
25 - 50
25 - 50
12 - 50
-
-
Bus Capacitance Energy Absorption (joules)
   340 VDC Nominal BUS
15.5
15.5
20
-
-
   75 VDC BUS with 4,000 µf
   (5 volt increase to 80 VDC)
-
-
-
1.5
1.5
Output Current Ripple Freq fS (kHz)
20
20
20
31.2
31.2
Minimum Motor Inductance l-l (mH)
5
2.5
1.25
-
-
   At 75 VDC
-
-
-
0.4
0.2
Maximum Motor Inductance l-l (mH)
300
150
75
30
15
Maximum Motor Power Cable Length4
   18 AWG cable (m)
50
50
50
50
25
   14 AWG cable (m)
50
50
50
50
50
  • 1 - Peak Output Current listed is for sine mode. In 6-step mode, the peak output currents are scaled to give the same output torque as in sine mode with a pure sinusoidal Back EMF motor. To convert ARMS to A (0-pk), multiply ARMS * 1.414.
  • 2 - Above 30° C ambient, linearly derate between provided 40° C, 50° C ratings. At higher ambient temperatures (above 30° C), the S20360 drive needs to be mounted on a thermally conductive surface to limit the heatsink temperature to less than 75° C.
  • 3 - Single phase operation of the S20660 requires derating of continuous output power to avoid excessive AC line front end currents.
  • 4 - See the Cable Voltage Loss vs. Cable Length table.