SynqNet.IdleCable

The cable id of an idle cable on a SynqNet network. An idle cable has no data traffic. It is the redundant network connection available in ring topologies only. A single ring topology has only one idle cable.

After network initialization, the cable from the last node to the controller is idle by default. If a network fault occurs and the network is configured for fault recovery, the network traffic will be redirected around the faulty connection, through the idle cable, and the faulty connection will become the new idle cable. To test the idle cable, read the SynqNet.IdleCableStatus property.

 This property cannot be saved to flash memory.

Version History

Introduced in MPX 2.0.

Arguments

 
Argument Type Description Default Value
Index Long

The index of the idle cable to read.

NOTE: This argument is intended for compatibility with future network topologies. Current network topologies support zero or one idle cable.

0

Type

Long (read only)

Visual Basic

Syntax

Property IdleCable(index = 0 As Long) As Long

Sample Code

 

x = Controller.SynqNet(0).IdleCable


Sample Application

 

C#

Syntax

 

 

Sample Code

 

See Also

IdleCableStatus

Node, Cable, Motor, Drive Addressing

 