LEDs: RMB-10V-SynqNet

 

Node LEDs on the
RMB-10V-SynqNet

  •  LED1 - Link Activity
  •  LED2 - Node State
  •  LED3 - Link Activity
  •  LED4 - Repeater
  •  LED5 - FPGA Boot Status
RMB-10V
The RMB-10V-SynqNet is shown above.

 

Each LED has a particular function which is described in further detail below.

Node LED Table
LED
Port
Meaning
Controlled by
Meaning
LED1
IN
Link Activity
PHY
ON = Link active. Normal Operation.
OFF = Link inactive
LED2
IN
Node State
MAC
ON = Tx and Rx are Active (Cyclic Phase) Normal Operation.
OFF = Unpowered, Reset, Inactive State. Network not cyclic.
Blink 2Hz = (Undiscovered State)
Blink 4Hz = (Discovered State)
Blink 8Hz = (SYNQ Recovery)
Blink 16Hz = (SYNQ Lost)
LED3
OUT
Link Activity
PHY
ON = Link active. Normal Operation.
OFF = link inactive
LED4
OUT
Repeater
MAC
ON = SYNQ operation is ON (Repeater ON). Normal Operation.
OFF = Unpowered, Reset, Inactive State (Repeater OFF).
Blink 4Hz = Tx and Rx are Active (Cyclic Phase)
Blink 8Hz = SYNQ Recovery
Blink 16Hz = SYNQ Lost
LED5
FPGA Boot Status
Repeater
MAC
(FPGA)
ON = no nodeAlarm. Normal Operation.
OFF = Unpowered or Reset
Blink = nodeAlarm. (node fault or network fault). See Node Alarm.

 

Node State Table
Node State
LED2
LED4*
Repeater OFF
Repeater ON
Unpowered
OFF
OFF
OFF
Reset
OFF
OFF
OFF
Undiscovered
BLINK .37Hz
OFF
OFF
Discovered
BLINK .75Hz
OFF
BLINK
(same phase as LED2)
SYNQ operation
ON
OFF
ON
SYNQ lost
BLINK 1.5Hz
OFF
BLINK
(opposite phase to LED2)
 
* - The repeater is OFF on all states when it is on the last node on the network.
       Legal Notice  |  Tech Email  |  Feedback
      