S200: Motor Current Control Specifications

NOTE: Unless otherwise specified, the specifications are worse-case limits and apply over the specified operating ambient temperature and over the specified operating line voltage.

Parameter
Rating
Motor Phase Current Waveform
(In Sine or six-step mode output torque = Motor KT* Drive IFB)
Pure sinusoidal or 6-step, depending on feedback device.
Motor Shaft Torque
(Ignoring motor magnetic saturation)
 
   Peak (hot motor winding)
   Multiply KT * 1.06 for cold motor    winding (AKM or PMA motors).
KT (N-m/ARMS) * Drive Ipeak (ARMS)
   Instantaneous
KT (N-m/ARMS) * IFB (ARMS)

 

Current Loop Bandwidth

Parameter
Rating
Maximum Bandwidth
   AC Input Drive (kHz)
3
   DC Input Drive (kHz)
5
Recommended Bandwidth
   AC Input Drive (kHz)
2
   DC Input Drive (kHz)
3
   SFD Auto Set (kHz) AC & DC
2
   Bandwidth Variation For Fixed Motor L
   (% regulated independent of bus voltage)
±2.5
   Update Period (µs)
0.8
Recommended Max Motor Electrical Frequency (Hz)
   AC Input Drive (Hz)
600
   DC Input Drive (Hz)
900

 

Offset Current

Drive
Typical
Worst Case Over Temp
S20250
0.2% / 12 mA
0.5% / 32 mA
S20260
0.2% / 12 mA
0.5% / 32 mA
S20330
0.2% / 25 mA
0.5% / 64 mA
S20350
0.2% / 25 mA
0.5% / 64 mA
S20360
0.2% / 25 mA
0.5% / 64 mA
S20660
0.2% / 50 mA
0.5% / 128 mA
S20630
0.2% / 50 mA
0.5% / 128 mA