SynqNet.TopologySave

Saves the current SynqNet topology to the controller's flash memory. After a power-on or network reset, the controller will compare the discovered network topology with the topology saved in flash memory. If all of the topology information matches, the controller will automatically transition the network to Synq (cyclic) mode. If the topology doesn't match, then performing the SynqNet.Initialize method will produce one of the following error codes:

ErrorSynqNetTopologyMismatch
ErrorSynqNetCableLength

WARNING: This is a low-level network routine that will clear other controller object configurations and reset the SynqNet network. This method should be executed in your application before performing other configurations.

Version History

Introduced in MPX 2.0.

Visual Basic

Syntax

Sub TopologySave()

Sample Code

 

Controller.SynqNet(0).TopologySave


Sample Application

 

C#

Syntax

 

 

Sample Code

 

See Also

TopologyClear

 