SynqNet.TopologySave Saves the current SynqNet topology to the controller's flash memory. After a power-on or network reset, the controller will compare the discovered network topology with the topology saved in flash memory. If all of the topology information matches, the controller will automatically transition the network to Synq (cyclic) mode. If the topology doesn't match, then performing the SynqNet.Initialize method will produce one of the following error codes: ErrorSynqNetTopologyMismatch WARNING: This is a low-level network routine that will clear other controller object configurations and reset the SynqNet network. This method should be executed in your application before performing other configurations. Version HistoryIntroduced in MPX 2.0. Visual BasicSyntax Sub TopologySave() Sample Code
C#Syntax
Sample Code
See Also
|