MEISqNodeConfigControlLatency

Definition

 
typedef struct MEISqNodeConfigControlLatency {
double minimum; /* uS - if > 0, this will insure a minimum latency value */ double maximum; /* uS - if > 0, an error will occur if this value is exceeded */ } MEISqNodeConfigControlLatency;
  Change History: Added in the 03.04.00.

Description

MEISqNodeConfigControlLatency is a structure that contains boundary values that ensure that the node’s Control Latency falls within a given range. The SynqNet configuration can be read with meiSqNodeConfigGet(...) and can be written with meiSqNodeConfigSet(...).

 
minimum

Lower limit for the control latency configuration. This will ensure that a minimum node control latency will be used in the SynqNet timing calculations.

Set to zero to disable minimum node control latency.

maximum

Upper limit for the control latency configuration. This will force mpiControlInit(...) or meiSynqNetInit(...) to return MEISynqNetMessageNODE_LATENCY_EXCEEDED if this value is exceeded.

Set to zero to disable maximum node control latency check.

See Also

MEISqNodeConfig | meiSqNodeConfigSet | meiSqNodeConfigGet | MEISynqNetTiming

Node Control Latency | Cable Length Discovery Uncertainty Factor | SynqNet Cable Length

 

       Legal Notice  |  Tech Email  |  Feedback
      
Copyright ©
2001-2021 Motion Engineering