ZMP-SynqNet Controllers:
   Hardware and Electrical Requirements

Environmental

Description
Operating Range
Operating Temperature
0-50 °C
Storage Temperature
0-85 °C
Humidity
20-90% RH
(no condensation)
Air Flow Requirements*
200 LFM
* If airflow is provided, on board
cooling fan is not required.

Power

Below is shown a table of basic host computer electrical requirements for ZMP-SynqNet controllers.

 

Controller

Voltage 1

Current
(Typ. amps)

Current
(Max. amps)

ZMP-SynqNet-PCI

+5 VDC ± 5%
2.2 A
3.0 A

+12 VDC ± 5%
(required for fan use)

0.1 A

 

0.5

ZMP-SynqNet-CPCI-3U

+5 VDC ± 5%
0.1 A
0.5 A
+3.3 VDC ± 0.3V
2.5 A
3.0 A


1. Controller voltage required at computer or card cage.

2. Power draw for ZMP-SynqNet-PCI: 8.28 watts typ.; 15.00 watts total.

 