Environmental

Description
Operating Range
Temperature
0-50 Deg. C
Humidity
20-90% RH
(no condensation)

Power

Below is shown a table of basic host computer electrical requirements for XMP-SynqNet controllers.

 

Controller

Voltage 1

Current
(Typ. amps)

Current
(Max. amps)

XMP-SynqNet-CPCI 2

+ 5 VDC
+ 3.3 VDC
+ 12 VDC
- 12 VDC

0.90
1.00
0.03
0.01

1.40
1.60
0.05
0.01

XMP-SynqNet-PCI

+5 VDC 2.00 3.00

XMP-SynqNet-PMC

+3.3 VDC

1.00

1.50


 

RMB-10V

Voltage 1

Current
(Typ. amps)

Current
(Max. amps)

XMP-SynqNet-RMB

+24 VDC ± 6 VDC

0.50

1.00

 


1. Controller voltage required at computer or card cage.

2. Power draw for XMP-SynqNet-CPCI: 8.28 watts typ.; 13.00 watts total.