Support for Analog Inputs

The RMB-10V2-SynqNet supports some analog inputs. The number of analog inputs a node supports can be determined with meiSqNodeInfo(...).

The state of an analog input value can be read with meiSqNodeAnalogIn(...). The analog value returned by meiSqNodeAnalogIn(...) is a signed integer between 7FFFh and 8000h. The analog inputs on RMB-10V2 nodes support software configurable input ranges. The rmbAnalogInRangeSet(...) and rmbAnalogInRangeGet(...) functions allow you to change the range of the analog data returned by meiSqNodeAnalogIn(...).

Type Code
7FFFh
8000h
RMBAnalogInRange10V
+10V
–10V
RMBAnalogInRange5V
+5V
–5V
RMBAnalogInRange2_5V
+2.5V
–2.5V
RMBAnalogInRange1_25V
+1.25V
–1.25V

 

 

 

 