Saving to Flash Table

It is important to know what is saved and what is not saved when you save an object in Motion Console. The table below summarizes what is actually saved when you use the Save to Flash feature.

NOTE: The mappings of objects to sub-objects are saved (ex: Motion Supervisor axes mappings), except in the case of SynqNet-to-Nodes-to-(I/O and Motors) and CAN-to-nodes-to-I/O.

Object
Saved
Not Saved
Notes
Controller Config tab,
Recorders tab,
Axis Map
Action tab,
Version tab,
Stats tab
 
Motion Supervisor Stop Time,
E-Stop Time,
Normal Feedrate,
Axis Map
Everything Else  
Axis Config tab,
Motion tab,
Status tab
 
Filter Config tab,
Coeff tab
  Post filters are saved, but are not shown in Motion Console.
Motor Config tab
(except Amp Enable),
Events tab,
SinCom tab,
Upper I/O tab

Amp Enable,
Home Trigger,
Encoder Fault Trig.,
Status tab,
(Lower) I/O tab

 
SynqNet   Config tab,
Info tab,
Status tab,
Axis Map (Save with SynqNet topology)
 
SynqNet Node Config tab
(except Upstream Err. Fault/Fail Limits)
Upstream Err. Fault Limit,
Upstream Err. Fail Limit,
Info tab
 
CAN Config tab

 

 
CAN Node Config tab    
I/O Motor I/O tab
(Type only, not Out or In)
SqNode I/O tab,
Motor I/O tab - Out and In,
CAN I/O tab
 

 