Trust TA801-E

 

Parameter Specification
Node Type
0x00090001
Option
0x00000001
FPGA
0xC0FE002D
Motor Count
1
Drive Count
0
Secondary Encoder Count
0
SqNode Digital Out Count
0
SqNode Digital In Count
0
SqNode Analog In Count
0
SqNode Analog Out Count
0

 

Parameter Motor0
Capture Count 1
Probe Count 1
Pulse Count 0
Dedicated In 0 - Amp Fault 1
Dedicated In 1 - Brake Applied 1
Dedicated In 2 - Home 1
Dedicated In 3 - Limit HW Pos 1
Dedicated In 4 - Limit HW Neg 1
Dedicated In 5 - Index Primary 1
Dedicated In 6 - FeedbackFault 1
Dedicated In 7 - Captured 0
Dedicated In 8 - Hall A 0
Dedicated In 9 - Hall B 0
Dedicated In 10 - Hall C 0
Dedicated In 11 - Amp Active 0
Dedicated In 12 - Index Secondary 0
Dedicated In 13 - Warning 0
Dedicated In 14 - Drive Status 9 0
Dedicated In 15 - Drive Status 10 0
Dedicated Out 0 - Amp Enable 1
Dedicated Out 1 - Brake Release 1

 

Motor General Purpose
I/O Bit
Name Valid Configurations
0 0 XCVR A Output, Pulse A, Pulse B, Brake, Input
0 1 XCVR B Output, Pulse A, Pulse B, Brake, Input
0 2 XCVR C Output, Pulse A, Pulse B, Brake, Input
0 3 XCVR D Output, Pulse A, Pulse B, Brake, Input
0 4 HSCAP Input
0 5 HALL U Input
0 6 HALL V Input
0 7 HALL W Input
0 8 DTS 0 Output, Pulse A, Pulse B, Brake
0 9 DTS 1 Output, Pulse A, Pulse B, Brake
0 10 USER OUT Output, Pulse A, Pulse B, Brake
0 11 USER IN Input

 

 

       Legal Notice  |  Tech Email  |  Feedback
      
Copyright ©