SQIO-HSIN32: Isolation

Digital Inputs

A creepage and clearance distance of 1.52mm (0.060”) is maintained between the inputs and all other circuits.

Assuming that the local environment is pollution degree 1 and over voltage category II “known and controlled transient voltages,” this spacing according to

 
  • table D4 of IEC61010 corresponds to 300V of basic insulation.
  • table 35.2 of UL508C corresponds to 450V of isolation in equipment of 500VA rating or less and 225V or isolation for equipment rated 500VA-10kVA.


The purpose of the isolation is to avoid grounding problems and resist radio-frequency interference. It is not intended that the inputs should be connected to signals whose steady-state potential difference from ground exceeds 42.4Vdc.

 

 

       Legal Notice  |  Tech Email  |  Feedback
      
Copyright ©
2001-2021 Motion Engineering