SQIO-DIN32DOUT32: Input Pinouts

NOTE: The common connections are per bank and are independent of the 24V supply to the SQID.

DB-25; P4

Pin
Signal
(sort by pin # )
Description
MPI
20
B0_DIN_0 User Input meiSqNodeDigitalIn(sqNode,0,0,&state);
8
B0_DIN_1 User Input meiSqNodeDigitalIn(sqNode,1,1,&state);
21
B0_DIN_2 User Input meiSqNodeDigitalIn(sqNode,2,2,&state);
9
B0_DIN_3 User Input meiSqNodeDigitalIn(sqNode,3,3,&state);
22
B0_DIN_4 User Input meiSqNodeDigitalIn(sqNode,4,4,&state);
10
B0_DIN_5 User Input meiSqNodeDigitalIn(sqNode,5,5,&state);
23
B0_DIN_6 User Input meiSqNodeDigitalIn(sqNode,6,6,&state);
11
B0_DIN_7 User Input meiSqNodeDigitalIn(sqNode,7,7,&state);
25
B0_COM Common for bank 0  
13
B0_COM Common for bank 0  
1
B1_DIN_0 User Input meiSqNodeDigitalIn(sqNode,8,8,&state);
14
B1_DIN_1 User Input meiSqNodeDigitalIn(sqNode,9,9,&state);
2
B1_DIN_2 User Input meiSqNodeDigitalIn(sqNode,10,10,&state);
15
B1_DIN_3 User Input meiSqNodeDigitalIn(sqNode,11,11,&state);
3
B1_DIN_4 User Input meiSqNodeDigitalIn(sqNode,12,12,&state);
16
B1_DIN_5 User Input meiSqNodeDigitalIn(sqNode,13,13,&state);
4
B1_DIN_6 User Input meiSqNodeDigitalIn(sqNode,14,14,&state);
17
B1_DIN_7 User Input meiSqNodeDigitalIn(sqNode,15,15,&state);
6
B1_COM Common for bank 1  
19
B1_COM Common for bank 1  
5
NC Not Connected  
7
NC Not Connected  
12
NC Not Connected  
18
NC Not Connected  
24
NC Not Connected  

 

DB-25; P5

Pin
Signal
(sort by pin #)
Description
MPI
20
B2_DIN_0 User Input meiSqNodeDigitalIn(sqNode,16,16,&state);
8
B2_DIN_1 User Input meiSqNodeDigitalIn(sqNode,17,17,&state);
21
B2_DIN_2 User Input meiSqNodeDigitalIn(sqNode,18,18,&state);
9
B2_DIN_3 User Input meiSqNodeDigitalIn(sqNode,19,19,&state);
22
B2_DIN_4 User Input meiSqNodeDigitalIn(sqNode,20,20,&state);
10
B2_DIN_5 User Input meiSqNodeDigitalIn(sqNode,21,21,&state);
23
B2_DIN_6 User Input meiSqNodeDigitalIn(sqNode,22,22,&state);
11
B2_DIN_7 User Input meiSqNodeDigitalIn(sqNode,23,23,&state);
25
B2_COM Common for bank 2  
13
B2_COM Common for bank 2  
1
B3_DIN_0 User Input meiSqNodeDigitalIn(sqNode,24,24,&state);
14
B3_DIN_1 User Input meiSqNodeDigitalIn(sqNode,25,25,&state);
2
B3_DIN_2 User Input meiSqNodeDigitalIn(sqNode,26,26,&state);
15
B3_DIN_3 User Input meiSqNodeDigitalIn(sqNode,27,27,&state);
3
B3_DIN_4 User Input meiSqNodeDigitalIn(sqNode,28,28,&state);
16
B3_DIN_5 User Input meiSqNodeDigitalIn(sqNode,29,29,&state);
4
B3_DIN_6 User Input meiSqNodeDigitalIn(sqNode,30,30,&state);
17
B3_DIN_7 User Input meiSqNodeDigitalIn(sqNode,31,31,&state);
6
B3_COM Common for bank 3  
19
B3_COM Common for bank 3  
5
NC Not Connected  
7
NC Not Connected  
12
NC Not Connected  
18
NC Not Connected  
24
NC Not Connected  

 

 

       Legal Notice  |  Tech Email  |  Feedback
      