Drive FPGA Table:
AMC DigiFlex® DQ111SE

Parameter Specification
Node Type
0x0001A001
Option
0x00000003
FPGA
0x00010011
Motor Count
1
Drive Count
1
Secondary Encoder Count
1
SqNode Digital Out Count
0
SqNode Digital In Count
0
SqNode Analog In Count
0
SqNode Analog Out Count
0

Motor 0

Capture, Probe, Pulse

Parameter Number
Capture Count 1
Probe Count 1
Pulse Count 0

Dedicated I/O

Parameter Supported?
Dedicated In 0 - Amp Fault Y
Dedicated In 1 - Brake Applied Y
Dedicated In 2 - Home Y
Dedicated In 3 - Limit HW Pos Y
Dedicated In 4 - Limit HW Neg Y
Dedicated In 5 - Index Primary Y
Dedicated In 6 - FeedbackFault Y
Dedicated In 7 - Captured N
Dedicated In 8 - Hall A Y
Dedicated In 9 - Hall B Y
Dedicated In 10 - Hall C Y
Dedicated In 11 - Amp Active Y
Dedicated In 12 - Index Secondary Y
Dedicated In 13 - Warning Y
Dedicated In 14 - Drive Status 9 N
Dedicated In 15 - Drive Status 10 N
Dedicated Out 0 - Amp Enable Y
Dedicated Out 1 - Brake Release Y

General Purpose I/O

General Purpose
IO Bit
Name Valid Configurations
0 User Output 0 Output
1 User Output 1 Output
2 User Output 2 Output
3 User Output 3 Output
4 User Input 0 Input
5 User Input 1 Input
6 User Input 2 Input
7 User Input 3 Input
8 Virtual Output 0 Output
9 Virtual Output 1 Output
10 Virtual Output 2 Output
11 Virtual Output 3 Output
12 Virtual Input 0 Input
13 Virtual Input 1 Input
14 Virtual Input 2 Input
15 Virtual Input 3 Input

 

 

       Legal Notice  |  Tech Email  |  Feedback
      
Copyright ©
2001-2021 Motion Engineering