.

Release Note
xxx_9601.fpg

MPI Version
FPGA Version
03.01.01
224_9601.fpg
03.01.00
Production Release
221_9601.fpg

  Table of Contents
     
    Changes and Bug Fixes
     

224_9601.fpg
     Rincon rxOutPort flicker - Fixed Bug - FP241

223_9601.fpg
     Rincon rxPropDelay cable length 0 - Fixed Bug - FP236

222_9601.fpg
     Rincon upstream packet errors during recovery - Fixed Bug - FP222
     Addition of Rincon opto input debounce filter - New Feature - FP221

221_9601.fpg
     Rincon rxPropDelay hang on ZMP - Fixed Bug - FP209


224_9601.fpg

  Rincon rxOnOutPort flicker
    Reference Number: FP 241
    Type: Fixed Bug
    FPGA Version: 224
   

Description:
The rxOnOutPort bit may not be valid in the Receive Control Block status word. This does not affect basic operation, but may cause problems with idle cable detection after fault recovery (only if the system has more than 16 nodes). This problem depends on internal FPGA routing delays, and potentially exists in all builds prior version 224. Currently, the problem has only been observed in 223_A301.fpg.

 

223_9601.fpg

  Rincon rxPropDelay cable length 0
    Reference Number: FP 236
    Type: Fixed Bug
    FPGA Version: 223
   

Description:
XMP and eXMP controllers using FPGA versions 221 and 222 always discover cable lengths of 0. The MPI schedule will allow for actual cable lengths between 0 and 10 meters, but longer cables may not work reliably. ZMP controllers are not affected by this bug.

 

222_9601.fpg

  Rincon upstream packet errors during recovery
    Reference Number: FP 222
    Type: Fixed Bug
    FPGA Version: 222
   

Description:
When fault recovery occurs on a network with 9 or more nodes, excessive upstream packet error counts may be seen for all nodes, or some nodes may fail to recover. The errors occured if a CHANGE packet arrived while the receive FIFO was reset at the begining of the next controller cycle. This problem exists in all FPGAs prior to version 222.


  Addition of Rincon opto input debounce filter
    Reference Number: FP 221
    Type: New Feature
    FPGA Version: 222
   

Description:
A debounce filter has been added to all 6 opto inputs of the XMP and ZMP controller designs. The filter delays input changes 140 uS +/– 20 µS, with the delay restarting if the input bounces back to the previous value.

 

221_9601.fpg

  Rincon rxPropDelay hang on ZMP
    Reference Number: FP 209
    Type: Fixed Bug
    FPGA Version: 221
   

Description:
ZMP controllers may fail network initialization. Typically, the application (Motion Console, reset, etc.) will never complete initialization. For MPI releases prior to 03.01.00, the application halts and never reports an error. The program can be aborted successfully in some cases, while others require a reboot to fully recover. Occasionally, the host computer may hang. For MPI releases 03.01.00 and later, the application will report an error. This problem exits on all ZMP controllers prior to FPGA version 221. XMP controllers are not affected.


       Legal Notice  |  Tech Email  |  Feedback
      
Copyright ©
2001-2021 Motion Engineering