Version 01.21.48
     Improvements to "Choose Another Recorder" dialog box - 1270

 

    Bug Fixes
     

Version 01.21.46
     Time scale on Motion Scope isn't refreshed upon sample rate change - 852

 


General Changes

01.21.48

  Improvements to "Choose Another Recorder" dialog box
    Reference Number: 1270
    Type: General Change
    Motion Console Version: 01.21.48
   

Description:
"Active" means that the Recorder is currently recording data. The preceding sentence has been added to the "Choose Another Recorder" dialog box. More explicitly, a Recorder is considered "InActive" either if the MPIRecorderStatus.enabled bit is not set (as returned by a call to meiControlRecorderStatus) or if both the MPIRecorderStatus.enabled and MPIRecorderStatus.full bits are set. The latter case is interpreted as the Recorder as having been "abandoned" as it is full of data that has not been retrieved.

 

Bug Fixes

01.21.51

  Modify button does not work on Group highlighted traces
    Reference Number: 1351
    Type: General Change
    Motion Console Version: 01.21.46
   

Description:
If you select the group name in the Group highlighted traces window and click the Modify button, no action will occur.

This feature is actually working as intended. When the Modify button is pressed, the currently highlighted Traces will be associated with the highlighted Group. Before the Modify button is pressed, the user can select or de-select individual Traces using the Control and/or Shift keys. If no Traces have been added or removed from the Group after selecting a Group, then pressing the Modify button will appear to do nothing. In other words, the Modify button sets the association of a set of Traces with a Group. If no changes have been made in the membership set of Traces, pressing the Modify button will do nothing. 


01.21.46

  Time scale on Motion Scope isn't refreshed upon sample rate change
    Reference Number: 852
    Type: General Change
    Motion Console Version: 01.21.46
   

Description:
When the sample rate on the XMP is changed, Motion Scope is not aware of it. Motion Scope checks the XMP sample rate at various points in its operation and updates the X-axis scale to reflect any changes. This will change the appearance only if the X-axis units selected is in milliseconds (i.e., not in samples). Motion Scope now checks the XMP sample rate when a new Pane is opened, when the Pane Mode dialog has been used, whenever Traces are reconfigured, and whenever the Arm/Go button is pressed. This problem was fixed.


 