Release Note
Motion Console
Motion Console Version |
MPI Release |
Release Date |
04.01.06 |
|
20Jan2006 |
04.01.05 |
|
20Oct2005 |
04.01.03 |
|
26Aug2005 |
04.01.03 |
|
29July2005 |
New Features
04.01.01
|
Display Segment number in label for SqNode I/O object |
|
|
Reference Number: 1181 |
|
|
Type: New Feature |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
In the I/O Summary window, under the SqNode tab, the segment number for the I/O object is now displayed.
|
|
Add a button that resets the CAN network |
|
|
Reference Number: 1178 |
|
|
Type: New Feature |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
A button has been added to the CAN summary window that resets the CAN network.
|
|
Display the next network object for SynqNet and SqNode objects |
|
|
Reference Number: 1177 |
|
|
Type: New Feature |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
For the SynqNet object and all the SqNode objects, the next network object on the network is now displayed.
|
|
Display MPIAxisConfig.estopModify attributes |
|
|
Reference Number: 1176 |
|
|
Type: New Feature |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
The following new MPI attributes have been added to the Axis Summary window:
E-Stop Modify Deceleration
E-Stop Modify Deceleration Jerk
E-Stop Modify Jerk Percent
|
|
Add User labels for objects |
|
|
Reference Number: 1161 |
|
|
Type: New Feature |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
Configurable labels have been added to several object types in the MPI. These will be made accessible through the object summary windows under the Config tab.
|
04.01.00
|
Add Support for Four new Dedicated Inputs |
|
|
Reference Number: 1138
|
|
|
Type: New Feature |
|
|
Motion Console Version: 04.01.00 |
|
|
Description:
The following dedicated motor I/O bits are now displayed on the Motor I/O status page:
MPIMotorDedicatedInDRIVE_STATUS_9
MPIMotorDedicatedInDRIVE_STATUS_10
MPIMotorDedicatedInFEEDBACK_FAULT_PRIMARY
MPIMotorDedicatedInFEEDBACK_FAULT_SECONDARY
|
General Changes
04.01.06
|
MEIMotorIoTypeSOURCE6 swapped with MEIMotorIoTypeBRAKE |
|
|
Reference Number: 1252 |
|
|
Type: General Change |
|
|
Motion Console Version: 04.01.06 |
|
|
Description:
In the MPI, MEIMotorIoTypeSOURCE6 was swapped with MEIMotorIoTypeBRAKE. A similar change was corrected in Motion Console.
|
04.01.03
|
Filter->Coeffs tab does not automatically choose filter labels |
|
|
Reference Number: 1152 |
|
|
Type: General Change |
|
|
Motion Console Version: 04.01.03 |
|
|
Description:
The labels for Filter->Coeffs tab always need to be set. This has been improved a couple of ways:
- The ini file remembers the Filter label type. This eliminates most user interaction on this issue.
- When a new Filter Summary window is created, Motion Console looks to see if all the filter types are the same, and if
so, chooses that filter label.
|
04.01.00
|
Update CAN and Control I/O |
|
|
Reference Number: 1158 |
|
|
Type: General Change |
|
|
Motion Console Version: 04.01.00 |
|
|
Description:
Use new MPI I/O methods associated with the CAN and Control objects to tap into extra functionality:
- CAN analog out is displayed as a signed integer.
- Control I/O has descriptive labels.
|
|
Use MEIMotorInfo to find out what I/O a node supports |
|
|
Reference Number: 1139 |
|
|
Type: General Change |
|
|
Motion Console Version: 04.01.00 |
|
|
Description:
New motor I/O methods added to the MPI are now used by Motion Console to allow displaying motor I/O that was not displayed before. Also, Motion Console now limits the choices for motor I/O types to only those that make sense.
|
|
Don't allow downloading a binary image to nodes of different types |
|
|
Reference Number: 1132 |
|
|
Type: General Change |
|
|
Motion Console Version: 04.01.00 |
|
|
Description:
If the user selects multiple SqNodes to download to, they must be of the same type.
|
|
Exponential notation in I/O is confusing |
|
|
Reference Number: 1106 |
|
|
Type: General Change |
|
|
Motion Console Version: 04.01.00 |
|
|
Description:
The Analog I/O in the I/O summary are shown in decimal notation unless they are very small, then they are shown in exponential notation. If it is zero, then it is shown as 0. When an ADC is flickering between +/- 1 lsb, it is difficult to read because the formatting is changing so fast. A similar problem arises when the ADC is near a round number. For example, there is a lot of format change when the ADC goes from 0.5 to 0.500031. Since there are no analog inputs with more than 16-bits of resolution, the analog inputs can be formatted in the following format: x.xxxxxx.
|
Bug Fixes
04.01.05
|
CAN analog output range limit should be -32768 to 32767 |
|
|
Reference Number: 1250 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.05 |
|
|
Description:
The CAN analog output range is currently set to be -1 to 1. It should be -32768 to 32767. This bug was fixed.
|
|
Changing multiple cells can cause a crash |
|
|
Reference Number: 1243 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.05 |
|
|
Description:
To recreate this bug, follow this procedure:
1. In the Motor Summary, Config tab, make sure that Amp Disable Action is "Cmd = Ac.t"
2. Select the entire "Type" row.
3. Set the type to "Stepper" and click on something else on the Config tab.
The error window should start to pop-up, but Motion Console crashes before it is fully displayed. This bug was fixed.
|
04.01.04
|
Motion Panic Action not compatible with older versions of Motion Console |
|
|
Reference Number: 1234 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.04 |
|
|
Description:
When the Filter Summary opens up initially, the algorithm on the Coeffs tab is automatically set and is based on its value
from the previous session. Unfortunately, the labels for the coefficients are not updated to reflect the algorithm. To get
the correct labels, the user has to change the display algorithm. This bug was fixed.
|
04.01.03
|
Motion Panic Action not compatible with older versions of Motion Console |
|
|
Reference Number: 1223 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.03 |
|
|
Description:
The Motion Panic action saved in the .INI file was not backwards compatible with older versions of Motion Console. Also, the value saved
using older versions of Motion Console was not forward compatible with the 04.01 branch of Motion Console. This has been changed
so that the values saved in the .INI file are now mapped back to their equivalent values in the MPI 03.02 branch. The
MPIActionE_STOP_MODIFY action was added in MPI 03.03.00 It is saved as E_STOP_MODIFY. This bug was fixed.
|
|
Motion Panic Action may default to NONE |
|
|
Reference Number: 1221 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.03 |
|
|
Description:
If the Motion Supervisor Panic Action in the .INI file is not a valid value, then the Panic Action will default to MPIActionNONE instead of MPIActionABORT. This bug was fixed.
|
04.01.02
|
E-Stop, Modify and E-Stop, Abort actions are reversed |
|
|
Reference Number: 1217 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.02 |
|
|
Description:
The entries in the event action combo-box for "E-Stop, Modify" and "E-Stop, Abort" need to be reversed. This bug was fixed.
|
04.01.01
|
Motor I/O Configuration Not Refreshed When Edited |
|
|
Reference Number: 1183 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
Typically, when an attribute is edited, its display value is synched up with the corresponding value on the controller.
This is not being done with Motor I/O objects. This can cause Motor configuration in Motion Console to be out of synch with the
controller because the Motor I/O configuration is really the Motor configuration. This bug was fixed.
|
|
Check List Combo Box not displayed correctly on second monitor |
|
|
Reference Number: 1182 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.01 |
|
|
Description:
The Check List Combo Box grid controls, such as the SqNode Alarm Mask, are not displayed on the second monitor in a dual monitor setup. This bug was fixed.
|
04.01.00
|
Pulldown boxes only work on primary monitor with a multiple monitor setup on win2k |
|
|
Reference Number: 761 |
|
|
Type: Bug Fix |
|
|
Motion Console Version: 04.01.00 |
|
|
Description:
When using Motion Console on a win2k system with multiple monitors, the pulldown boxes don't function on the secondary monitor, but do work on the primary monitor. This bug was fixed.
|
|